Stainless Steel welds in accordance with BS 7475 1991 by means of T.I.G. or M.A.G. process. Kent Stainless gullies and channels for the chemical and pharmacetuical industries are welded to weld procedure WP 1008 and can be tested to ASME IX (ref QW 200) testing standards. All welds are pickled and passivated to restore properties.
100% dye penetration on non-butt welds to BS 6443 radiography on 10% of non-butt welds to BS 2910 (where requested). |