Quality

Line drawings for an engineering project
  • ISO 9001:2015 accredited Quality Management System in operation companywide
  • EN 1090-2:2008 Factory Production Control Certificate – structural components and kits for fabricated structures
  • Fully compliant with the 2014 Construction Products regulation PR Directive on CE Marking
Visual inspection icon

Visual Inspection

Visual Inspection

At EVERY stage in the process a visual inspection takes place and is recorded in our Process Route Cards
Destructive testing icon

Destructive Testing

Destructive Testing

At prototype stage the first sample is tested to destruction and all strengths & weaknesses recorded on a timeline
Non destructive testing icon

Non-Destructive Testing

Non-Destructive Testing

15% of any production run is randomly pulled and tested. For the Pharmaceutical sector, a typical request is for 10% Radiography Testing
Dye penetration test icon

Dye Penetration Tests

Dye Penetration Tests

100% Dye Penetration tests on non butt welds to BS 6443
X Ray testing icon

X Ray Testing

X Ray Testing

Typically requested for Double Contained Drainage in the Pharmaceutical and Chemical sector – 10%of production run is tested on request.
Hydraulic testing icon

Hydraulic / Pneumatic Testing

Hydraulic / Pneumatic Testing

This test is generally carried out on our Double Contained Drainage products and our Double Walled Tanks & Vessels to 7 PSI test pressure
Submersion testing icon

Submersion Testing

Submersion Testing

Watertight Manholes are submerged in a specially constructed tank. Dye Penetration tests can be used in this tank to test seals.
Slip resistance testing icon

Slip Resistance Testing

Slip Resistance Testing

For drainage products in wet environments, the surface of the gratings are supplied in accordance with BS EN 7976 parts 1-3:2002 for slip resistant value of SRV36
RA testing icon

RA Testing

RA Testing

SRG4000 Surface Roughness tester is used to measure the RA value at goods inwards and after polishing ensuring compliance with EN10088
Flow testing icon

Flow Testing

Flow Testing

Drainage Flow rates are designed & tested to BS EN 1253-1:2003 and also to ASME A112.3.1-2007.
Wind load testing icon

Wind Load Testing

Wind Load Testing

Using Solid Works and Cosmos
Load testing icon

Load Testing

Load Testing

Physically tested on a test rig to FACTA Class A to E and DIN 19580 and EN124, EN1253, and prEN1433 load classes A15 to F900
Galvanising thickness testing icon

Galvanising Thickness Testing

Galvanising Thickness Testing

Hot Dip Galvanised coating supplied in accordance with BS EN 1461:2009. The amount of zinc coating covered by this standard is regularly exceeded for harsh coastal regions – 140 microns galvanised coatings are often applied and tested.
Fire rating icon

Fire Rating

Fire Rating

Products independently 3rd party certified by Exova Warringtonfire
Industry memberships icon

Industry Memberships

Industry Memberships

We are proud members of the following Industry Organisations: IBEC, FACTA, BSSA, CPD Certification Service, ISPE, NBS - BIM Level 2